• Dominik Inführ's avatar
    [heap] Use base::SharedMutex in Heap::IsPendingAllocation · f2fd431a
    Dominik Inführ authored
    Use a read-write lock for protecting original_top, original_limit and
    pending_object for all spaces. This way Heap::IsPendingAllocation is
    always guaranteed to read a consistent top/limit-pair and also the
    last values for those fields.
    
    The main thread will acquire an exclusive lock to update those fields.
    Concurrent Turbofan threads will use shared locks to read them.
    
    This may be quite expensive on the Turbofan-side, so landing this CL
    should help us figure out how big of a regression this simple fix would
    be. For main thread execution performance is supposed to be okay, since
    this is only used on the allocation slow path.
    
    Bug: v8:11778, chromium:1213266
    Change-Id: I9464f53fd50057ec2540ab5b79f74ee52a5d7500
    Reviewed-on: https://chromium-review.googlesource.com/c/v8/v8/+/2903143
    Commit-Queue: Dominik Inführ <dinfuehr@chromium.org>
    Reviewed-by: 's avatarMichael Lippautz <mlippautz@chromium.org>
    Cr-Commit-Position: refs/heads/master@{#74814}