Ben Smith authored
The strex (Store Exclusive) instruction has the form: strex rd, rt, [rn] It stores the value in register rt at the address in register rn. If the store succeeds, then 0 is stored in rd, otherwise 1 is stored. The ARM manual says that behavior is "unpredictable" if d == n || d == t (i.e. those registers are aliased). We were not checking for this behavior in the assembler or simulator, and as a result were generating output where it occurred. This didn't always break; the tests we run on ARM hardware run this instruction and pass. BUG: chromium:786168 Change-Id: I57fe3a1db406eac96eb04ef2246f6970548d3cf9 Reviewed-on: https://chromium-review.googlesource.com/777777Reviewed-by: Benedikt Meurer <bmeurer@chromium.org> Reviewed-by: Mircea Trofin <mtrofin@chromium.org> Commit-Queue: Ben Smith <binji@chromium.org> Cr-Commit-Position: refs/heads/master@{#49513}
44c52f7b